ae2 me controller max size. But for whatever reasons some are already. ae2 me controller max size

 
 But for whatever reasons some are alreadyae2 me controller max size A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage

But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. Place the storage bus on the ssn controller and use the cable to connect to your ae2. for me craft i for 5x5x5 with 50% cpu, my crafting normaly gets stuck waiting on one machien (i. Controller mutliblock has to fit within a 7x7x7 - again, not too bad. This Solution's Drawback is using 2 Channels, so you'll need two lines of Dense Cables to run 32 Modules. You specify the region and put in a Spatial Cell (2 16 or 128 and give the IO port a redstone signal. 10 ae2 was just to annoying and it felt as if they ruined my favourite mid but thank you for this post cause I like the concept of everything ae2 stands for like the inscribed and meteorites to make things but growing certus and channels mad me think wtf did he do. size unless you do something like the last pic. Specialised cells for certain conditions also do not make much sense as the idea for AE2 is still to provide as few basic options as possible, while allowing the player to combine it to fit their needs. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable and turn white. A couple facts: Each side of the controller can handle up to 32 channels. Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. AE 2's channel system, with the maximum amount of channels being 32, seems to suggest that it isn't. it can be hollow, but be careful, some of the outer ones will deactivate, you will have to add holes. The Controller will need power to work. Synopsis []. You configure the connections by using the ME Bus Memory Card; First Shift+Right Click the input to save it on your memory card, then simply right click the diffrent outputs to store the input onto the. If there's "Extra Cells 2" in your pack, the biggest storage cells are 16M (instead of 64k). Get the configuration of the interface. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright. . The ME Quantum Network Bridge device is a multiblock unit capable of connecting distant ME networks together. Youd. Whenever you have more than 8 devices in a network, an ME Contr. Since all the tunnels connect directly to the controller and are equal to a length 1 hop, the channels will never route sideways through the machines. wireless. Top 1% Rank by size . Not too shabby. 771. Applied Energistics 2: ID Name : appliedenergistics2:item. The problem is as of now you can get 2304 channels in a 3x3 with all the centers punched out so it’s hard to beat that. AE2 Network Tool GUI. It has to be touching the drawer bank. One ME P2P tunnel may pass along 32 channels of data using just a normal covered or smart cable, and up to 4 PAIRS of tunnel nodes may exist on such a cable (8 total nodes for one channel each). 5. You always have hoppers as well. Controller mutliblock has to fit within a 7x7x7 - again, not too bad. 180. Has 8 channels to play with. It is the new and overhauled version of the original Applied Energistics mod. Channels. The ME 1k Storage cell is the smallest and easiest to craft to get started, and can easily. Ah ok, so just a bigger set up I guess. 1. For every 32 drives, you'll need one P2P tunnel on the controller. While the ME Chest is a great way to get introduced to the concept of ME, to really take advantage you need to. . With the network tool you can get the maximum consumption capacity (and current charge). No branches or pull requests. a controller with infinite channels. ME Controllers are thus disabled as a result, so anything relating to the. . Pick a (big) number, try it. You really need to count channel usage right at the controller. I just use a normal reactor with a huge capacitor bank to store power. The ME crafting terminal from ae2 tutorial. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. 解説にあたって. 10 now I'm trying to replicate my old setup without luck. Basically, what this means is that of the 3 axis of the block (Up/Down, East/West, North/South) only one of them may have. No cards, no items, only. (2) One chest. Also, AE2 uses priorities intelligently. I wouldn't suggest a turbine until you can use the power of a max size one which is 80 blades, uses 2000 mb/t of steam, and produces around 27k RF/t depending on the power multiplier in the configs. It is the main part of any ME Network which handles everything like a CPU does in your computer. While holding shift will extract a full stack. Use multiple cells/drives. RS's versions have Stack and Speed Upgrades which both. . is the Fools one, which is about 7 idle days of waiting. #2. (4th picture) So if you make each set of the controllers max size and have all the faces connect to the center network you can have ALOT of channels. The max channels the wireless connector can pass is 32, I believe you may be able to P2P more channels through it, but I haven't tried in a year. Also a 3x3 square would not work due to the way they work. 14. This means you can send one kind of power into machines never designed to work with it, which causes major balance issues. Cheers!The ME Controller is a block added by the Applied Energistics 2 mod. Not connected to same dense cable. For the easiest way to automate inscribers, you need: (1) One ME interface. After making the room proper, I discovered that the drawer controller can control drawers that are 12 blocks away from the controller in any direction. For logistic pipes, you have xnet for automation, and you could rush integrated dynamics. them outside the network. (5) some EnderIO basic conduit filters. Applied Energistics 2 (以下AE2)上級者を目指すためにいろいろとテストしてわかった他のMODにはないAE2独自の輸送特性についてのメモも含めた解説記事となります. 前提MODとして LibNine ・ Applied Energistics 2 を導入する。. Join. Development. you want interfaces to be completely covert with assemblers for maximum efficency and speed interfaces/assemblers can only transfer up to 8 channels, so that would be your max. None yet. If dyed, cables will not connect to ones of a different color, which makes it easier to have many networks close together. More than enough channels. For convenience, you need to attach a dense cable on each side of a controller except those four that are in the inside circle. In this video I will go through next tier of ME Networks, when the ME Controller is required. setInterfaceConfiguration ( [slot:number] [, database:address, entry:number [, size:number]]):boolean. Any data-storing or data-using device needs a channel. Basically the ME Controller and the ME Drives need to be in the same chunk, even if the ME Controller is split between 2 chunks and the cable you are using stays in 1 chunk it will still lag like crazy. Use multiple cells/drives. 128³ Spatial Storage. It is used to charge charged items and charge Certus Quartz Crystals into Charged Certus Quartz Crystals. Just put one ME Storage Bus on the Drawer Controller. Layers alternate ME interfaces connected to the dense cable, so each ME interface has access to 3 (top/bottom) or 4 assemblers. That means it could provide a bus for 32 ME drives with 10 16M storage cells each. An expandable and versatile advanced data storage system with a multitude of applications. 7. AE2 ME Controller Keeps Flickering. items in storage drawers and connect the controller to the ME network with a storage bus. 12. Or just do the level emitter thing, or external automated crafters and pre. I'm going to try adding another ME Controller to increase the channel limit, but. Depends on what you're running though. In the network tool GUI of AE2 (access by right clicking an AE2 device on a ME network such as a cable), there is a title "network details", followed by "stored power" (0 RF [0 AE] , as there is no energy cell and I'm powering via tesseract), max power (16 kRF [8 kAE]), then a list of AE2 devices on the network. 2; Forge; Nov 7, 2023;. 5 5.入出力端末を作る. Each face of a controller can have a bundled cable attached to it. 3. Reasons why it should be considered Symmetry - fans would be happy. Side note: this is being done in the mining dimension since server restrictions keep me from doing all this in my main stoneblock base. Edit 2: I solved it! I don't know what it was that was causing the items to disappear but I just tore out all the ME controllers and replaced each cable connection one by one to try and find the one causing the problem, but after I did that it just went back to normal. Crafting CPU. Im happy to present you MyModpackList a site inspired by MyAnimeList and allows you to make your own list of modpacks you want to. My Very First Quartz. E. Technicaly it doesn't, but it's the only way to get the max channels out of many shapes of controllers. Many mods also offer a similar feature, but all i know of are worse and meant for earlier in progression than AE2. After the move I. 000,- if you set it up with only 64k units (no co unit, no crafting monitor). You can tell this by watching the AE controller energy go above its max amount before resetting back to its max amount and repeating. Basically, what this means is that of the 3 axis of the block (Up/Down, East/West, North/South) only one of them may have. However!At the moment, my ME System is located underneath my Incense Altar Pyramid (Max size), but I am considering moving after I find a new base location. Prior to implementing Applied Energistics, I had 6 full silver chests. There are limits to the number of devices you can have in a system (I think 8 without a controller, and then it's limited to the connections to the controller), but, as far as I can tell, all the devices can be interchangable, you could have 8 ME drives as a system, you just wouldn't be able to actually DO. 4 4.MEネットワークを構築する. With the standard 1 EU = 4 RF conversion. AppliedEnergistics / Applied-Energistics-2 Public. MK234. It is used to connect the components of a ME Network. Join. RS is far better if you don't want complexity and you aren't building a large system. ) and Energy Units (EU). • 4 yr. I believe TKH made a controller that gave him 22841 channels at his disposal. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable and turn white. 大容量チェストMODとして. Add a Comment. Get to know AE2 in a new way! - Download the Minecraft Mod AE2 Additional Opportunity by Domaman202 on Modrinth. You could have 32 Input P2P tunnels feed into one dense cable and then into one side of a Controller, and the output tunnels will be on the other side of the controller. Everything on that side of the P2P can have its own ME Controllers, interfaces, channel counts, etc. The size of the ME Controller must be within 7x7x7; else it will turn red. ME Storage Cell are used to store items; for example, possessing a 64k ME Storage Cell allows the player to store up to. When you create a P2P into a dense cable, you are converting 32 channels from 1 facing into 1 channel. I'll tell you what are the differences between them, How to build a Hilber. Time to head for EMC a. (6) some EnderIO energy conduits for the power supply (if you want to be compact - they can share the space with the item conduits)OMFG THXS I loved ae1 and was heart broken when ae1 didn't get updated to 1. There can only be one on a single network, if you put multiple the whole network will lock up, and the controllers will turn red. i currently have 2 energy acceptors connected to the same glass cable, and the. Featured playlist. The ME Controller is a multiblock structure, the minimum being 1x1x1 and the max being 7x7x7. Sort by:Possible Upgrades. More posts you may likeDrawer A. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright. 17. 6 P2P MLG Pro . As. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits (initially -> false) - allows you to install several. When this block touches other storage-drawers it acts like an extension. Ah ok, so just a bigger set up I guess. A single block controller could take in 3 dense cables and output 3 dense cables, meaning you would have access to 3 * 32 * 32=3072 channels from a single block controller. Use a quartz cable to connect the smart cable to the ME controller hub, the huge one and remove the intermediate controller. 3. #minecraft #moddedminecraft #appliedenergistics2 toastonrye's AE2 Setpoint Controller, a work in progress!A weekend project I'm probably never going to finis. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. The only recent modification was the addition of 2 more vertical levels on the casters. The AE2 Stuff Network Visualisation Tool obviates the need for a mess of colored cables, too. About 1/4 machine automation, 1/4 autostocking, and the rest crafting interfaces. Here's the math and facts: 188 ME Controller blocks. That's 32x32 channels (1,024) going through a single dense cable line. The ME System is used for storing items without using up much physical space. Considering the vanilla item system, AE2 is even great at handling non-stacking items as long as their data is consistent (in particular, freshly crafted items). Applied Energistics 2; Main File 1. I just logged on and now its doing nothing at all :S really strange, i can access the system/items but its not processing anything and there are still ores and dusts in the system, also there. Top 3% Rank by size. Applied Energistics 2: ID Name : appliedenergistics2:item. SSD can have as many of these ad-hoc networks as you want. The mod includes a network-based storage sy. The "Energy Acceptor" block was modified to allow EU, RF, Tesla, etc. One actively pulls items, one passively accepts items. All reactions. You may be looking for ME Controller from Applied Energistics . So what is the most channels you could get? The size of the ME Controller must be within 7x7x7; else it will turn red. Set the level controller to 1000 torches and point it at an export bus for torches with a crafting. The ME Controller is the core machine required for any Applied Energistics network. ME Controller · ME Power Relay. ago. Additional Context. ---> I only have 3 blocks in a row. 2 In Conclusion . All the stuff along the outside could be improved and you could easily add a couple of hundred by not having everything feed back into the controller as I did. malicious_bloke. The conversion is 4 RF -> 2 AE <- 1 EU. 2. Gaming. Applied Energistics is a Minecraft Mod which contains an advanced storage system called ME that lets you store items compactly and in the way you want, as well as do intricate automation. The Controller has the ability to transmit data throughout the ME Network using 32 channels per side. Seems weird that it wont try to take a different route that's the same length to the controller. Part of a multi-block structure, used to digitally store the blocks within a certain space determined with the use of the Spatial Pylon. 12. I imagine one day I'll need those extra channels in which case I'll rip out this design and likely opt for the max size beast. 0:00 / 9:22. But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. The P2P network will transfer power, but won't use power it's transfering. The maximum amount of items a Storage Bus can work with reliable with full Capacity Upgrades is 63 different items. The Drawer Controller can coordinate the function of all connected drawers within a 12 block range along any axis. 25kRF/t generated and consumed, but when the autocrafting is going it drains the pitiful reserves of the controllers (16kRF/controller, max power is 304. Minecraft Version: 1. Although the chest's storage capacity is limited to one Cell, it has it's purpose. cfg" and open -> Find the following ->. It is still awesome. So in my picture you can kinda see a fluix cable running along the bottom of the controllers - this is attached to the controllers with quartz fiber (which allow AE2 power. It accepts energy in from most sources, such as EU and MJ and provides it to the machines connected to it. Only one can be used as input, with any number of outputs. Theinventor10. I've read similar problems posted on this subreddit and. AE2 hasn't really changed mechanically since it's inception as far as I'm aware, so as long as it's AE2, even if it's an older version of minecraft, the guide will still work fine. I think that the most efficient controller possible doesn't have any loops- that is, the controller blocks form a long, perhaps branching, chain. Once our network grew to a certain size, with multiple quantum bridges and numerous storage mediums added, we starting having troubles with things disappearing from our ME network. Tunnels are 1 input to N outputs. You can use 32 interfaces. Use quartz to supply power and short-circuit the ME signal (force it to go through the p2p); just go around the p2p with quartz. For any more channels you need a controller but if your just using a couple drives ad hoc should work perfectly for nowApplied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). Unlike the ME Chest, the items that are stored inside the storage cells cannot be directly accessed; instead the drive must be connected to a ME Network which allows. It is the new and overhauled version of the original Applied Energistics mod. That means it can transfer 16krf/t. Make sure that none of the cables of the same colors attach to each other, use different colors for cables and do not attach fluix cables directly to the. There can be one controller on a network at most. Here's something that uses. It also has its own power generator in the form of Vibration Chambers. Applied Energistics 2 est un mod créé par AlgorithmX2 qui permet de stocker efficacement des objets dans un réseau numérique appelé Matter Energy, ou ME (prononcé Emm-Euh). While hovering over an item that has a guide page, hold the W key to open the corresponding guide page. But what is interesting is that the "other side" of the P2P interface is actually managed like a second distinct ME network multiblock. Install the highest level of storage upgrade that you can on the drawers, and a void upgrade (which will delete anything going to a drawer that is. But it also means that they connect even if you don't want them to and you can get cross connections. Read below for info and updates on the s. 2. Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). To configure a P2P Tunnel you must first attune the tunnel to carry what you want it to, then you need to configure the outputs to their input. 31, no extra mods except client version of lag goggles to debug my base in-case of lag spikes. 이 블럭의 역할을 알기 위해선 우선 '채널'에 대해 알아야 한다. u/prozacgod came up with the idea of using a specific shape that has a large surface area that fulfils the maximum size of an ME Controller. You do not have to build the multiblock as a cube though. Connect up a few dense cables to the underside and all 30 interfaces connect fine. This configuration seems to allow me to have as much as 9408 channels and i know that i don't really need this many, but it's fun to reach the limits sometimes. extenders= the maximum number of wireless boosters ( capped at 64 ). With that many ME drives, you'll need a lot of power (at default conversion, 224 RF/t just for the drives if you used 1k storage cells in all of them, or 704 RF/t if you used 64k storage cells; the power draws caused by the crafting terminal, storage bus, and cables are trickier to calculate). AE2 itself adds Certus Quartz Crystal, and makes use of vanilla's Nether Quartz as well. 64k disks would store a lot more per disk, but the index is 4x the size. The ME Controller's texture will change to display the stored energy level for network use. 2 Steve's First Network . This is obvious but its still the best tip for ae2 but cable anchors can prevent cables that would otherwise connect from connecting. The 63 types is a non issue for me. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. Most devices such as standard cables, and machines can only support up to 8 channels. Do what you normally would to join 2 p2ps and see whether it works. I have a question regarding AE2. e. . This is a great feature. Key things to remember about channels: Each side of a controller block can support 32 channels. Functional Storage is an alternative take on the storage solution of Storage Drawers, with an updated look and additional functionalities like: Armory Cabinet: It stores 4096 non stackeable items (by default) and can only be accessed with external tools (currently) like Applied Energistics or Refined Storage external storage tools. ME Controller · ME Terminal ·. This allows the mod (Applied Energistics 2) to accept multiple forms of power, but not be a totally broken power converter. It also includes some examples of how to use basic. (16x16 area) Describe the feature: +1 range from the controller. As a sidenote here : Dont do massive Storage drawer arrays if you have an AE2 system use AE2 Storage cells, drawers in huge amount will lagg you to death at one point. The controller can also transmit an unlimited number of channels through itself. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. Neverthless I do not see many arguments to convince me about this option. wireless. Today we will. I didnt recognize the vibration chamber. 大容量チェストMODとして. That's 32x32 channels (1,024) going through a single dense cable line. 2 Steve's First Network . The ME System is used for storing items without using up much physical space. Required Tool. If you want some kind of storage- which in. As. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits. 適切に隣接させるとマルチブロックになる。. It is highly recommended following its specification and further considering an upper bound for the dependency version. If you want to do with with only AE2, then you are going to want to use sub-networks. . ・まとめ AE2のみでも、各種素材要求物の自動化や実質容量を劇的に増やすこともできる。単体導入や、MODPackに入っていた場合でも安心。 が、強いこだわりや複雑な施設による負荷を避けたいなら、アドオンの「AE2 Stuff」を同時に導入すると、面倒な自動設備を数ブロックに圧縮できるため. Easy solution, create a quantum bridge for each of your "corridors" and attach each to a dense cable coming off your controller, that'll give you 32 channels per corridor to play with. This structure can be built in any cuboid, or size as long as the following Criteria are met. 1 チュートリアル. It serves like a base to processors added by the mod. To summarize what everyone else is saying: if you want a "vanilla" AE2 solution use a quantum bridge otherwise, if you want to extend your System to the. In practice the amount of channels you actually need comes down to how much you intend to solve with AE2 and the modpack you are playing. • 8 yr. Don`t. 7. . Dense cables = 32 channel carrying capacity along the line. So for example, if you have an ME Cable facing all six sides, you can have a maximum (assuming no one cross-connects) of 48 channels from a single ME Controller. 2. I'm finding that when my ME network gets to a larger size (to the level of hundreds of connected interfaces/buses), it keeps freezing up. Each block will use 10 + distance 2 AE/t (configurable)I dont really understand Ae2 nearly as much as i see most people do here on this sub, but Im trying to setup a large crafting grid of a 3x3x3 block, alternating between ME Interface's and Molecular Assemblers. Now your next recipe should be named item 1 + the next 8 components = named item 2. Without a controller, an ME network can handle only up to 8 channels, with a controller it can handle more (well, 32 per side of the controller, as usual). How to make the inscriber, processors, fluix crystals, and complete setup. • 18 days ago. かまど燃料からAEエネルギーを生成する装置。. Nope. Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. It transmits ME Network data remotely to the synchronised Wireless Terminal allowing remote access to the Network storage. As I continue to dabble I may add in checking on the status of the requested jobs and bound the looping to when all requested jobs per loop-pass have been completed. Build a Storage Drawers system, connect the Drawer Controller to the ME system with a Storage Bus (this will allow the AE system to see everything in the Drawer System that is inside a 12x12 area). One thing you will need to know when making a multiblock is that each controller can touch no more than 3 other controllers to remain valid. But in Minecraft you need to. any rf/fe source can be used (either hooked up to the controller or an energy acceptor) Reply replyInscribers can go die in a fire. Channels are just a funny way to say bandwidth. Dense, P2P and Quantum Ring all support 32 channels. All the autocrafting bits and bobs are still there and operational. Time to head for EMC a. 1. Issues Source. Join. Yep, we finish the max size me controller, and get to the draconic staff of power and the philosopher's stone, just for good measure. So within rule 2, there are 6 corner blocks (max 3 connections), 60. Replace your RF power generator with a power acceptor from AE2. Manages a single auto crafting task from start to finsh, built of various crafting units. However ME Dense Cable can support up to 32 channels, the only other devices capable of transmitting 32 are P2P. 生産 :40AE/t. 25kRF/t generated and consumed, but when the autocrafting is going it drains the pitiful reserves of the controllers (16kRF/controller, max power is 304. 2 In Conclusion . com, stoneblock version is 1. ME Cable can also be colored with dyes. The current power level is indicated by a coloured bar on the front of the block. This is obvious but its still the best tip for ae2 but cable anchors can prevent cables that would otherwise connect from connecting. With the way tags and flattening works, it also would not be of much use. The rules for a valid SCS are, A minium size of 3x3x3 ( this will capture a single block. The ME Chest shows you the contents of the Cell as soon as its placed inside, and you can add and remove items from it as if it were a Chest, with the exception that the items are actually stored in the Storage cells, and not the ME Chest itself. Disble chanels limit; And settings for all upper; Setting for conroller max size; Setting for amount of item and fluid per byte . Jan 25, 2015. So will take the max amount the conduit can give (up to 80/400) and drain your reserves. Keep in mind that controllers are only really useful if you can get at them to make connections. This can be useful to move a multi-block stucture or a processing machine set-up. Flammable. There can only be one on a single network, if you put multiple the whole network will lock up, and the controllers will turn red. Applied Energistics 2 is the second and most modern version of the “Applied Energetics” mod by “AlgorithmX2”. Il s'agit d'une version nouvelle et améliorée du mod Applied Energistics original. ). A hollow 5x5x5 cube of controllers can provide channels to hundreds of interfaces without a p2p. You can make that thing look like a tree, with p2ps holding 8 channels each everywhere. That means it could provide a bus for 32 ME drives with 10 16M storage cells each. them outside the network. No idea what you're attempting but from the explanation I don't think it's possible. The AE2 CPU doesn't need a frame, which means you can have a big, pretty array of them. If you are using 2 p2p (one for input from the network and another for output) it would only be 4*32 = 128. More posts you may like. Connections are point-to-point - you can't connect more than 2 blocks together. Or so I heard. According to my own calculations, the maximum amount of items you can store is somewhere are 20,000,000. Any machine that is to be connected to a network requires 1 channel. The current AE2 developer has said that he does not want the storage system to be a power provider. It is still up to 1024 channels per QNB. As your base network grows larger and larger, you will need to have at least one ME controller to hook up more devices to the network (a single controller gives 196 channels, or up. Most AE2 user interfaces will also offer a help button to open the most relevant guide page. If you have smart, covered, or normal ME cables attached to dense cables, the dense cables still can carry the same 32 channels but the other cables can only continue up to 8 of those channels of the 32 in that line. Hilbert controller has 510, so you're looking at almost exactly 30% more faces. AE2 ME Interface → me_interface. does ANYONE know why there is no ME controller in the…. It accepts energy in from most sources, such as EU and MJ and provides it to the machines connected to it. Wiring has its own simple concepts that go along with this channel system: 0.